1Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06
Models:
QV32B
QV36B
Installers Guide
Underwriters
Laboratories Listed
- Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
- What to do if you smell gas
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
WARNING: IMPROPER INSTALLA-
TION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAM-
AGE. REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL INFOR-
MATION CONSULT A QUALIFIED IN-
STALLER, SERVICE AGENCY, OR THE
GAS SUPPLIER.
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERS
GUIDE MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.
1. This appliance may be installed in an af-
termarket, permanently located, manufac-
tured (mobile) home, where not prohibited
by local codes.
2. This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
Please contact your Quadra-Fire dealer
with any questions or concerns. For the
number of your nearest Quadra-Fire
dealer, please visit www.quadrafire.com.
Printed in U.S.A. Copyright 2006
WARNING: IF THE INFORMATION
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUS-
ING PROPERTY DAMAGE, PER-
SONAL INJURY, OR DEATH.
Quadra-Fire, a brand of Hearth & Home Technologies
1445 North Highway, Colville, WA 99114
This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471,
5328356, 5341794, 5347983, 5429495, 5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165,
6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, 6769426, 6774802,
6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250,
780403, 1418504 or other U.S. and foreign patents pending.
In the Commonwealth of Massachusetts:
installation must be performed by a licensed
plumber or gas fitter;
See Table of Contents for location of additional
Commonwealth of Massachusetts requirements.
Zobrazit stránku 0
1 2 3 4 5 6 ... 43 44

Shrnutí obsahu

Strany 1 - Installers Guide

1Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Models:QV32BQV36BInstallers GuideUnderwritersLaboratories Listed- Do not store or use gaso

Strany 2

10 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06For all side wall horizontally vented gas fueled equipmentinstalled in every dwelling, bu

Strany 3 - TABLE OF CONTENTS

11Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/062Getting StartedIntroducing the Village CollectionGas FireplacesThe Village Collection dir

Strany 4 - Service Parts

12 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06RATING PLATE/LABELSGASACCESSGASCONTROLSELECTRICALACCESSTOP STANDOFFSGASLINEACCESS5 1/16(1

Strany 5 - (NG, LP) Service Parts List

13Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Figure 2. Diagram of the QV32BÎRATING PLATE/LABELSGASACCESSGASCONTROLSELECTRICALACCESSTOP

Strany 6

14 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/063Installing the FireplaceStep 1. Locating the FireplaceSpace and clearance requirements

Strany 7

15Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Figure 5. Framing DimensionsStep 2. Framing the FireplaceFireplace framing can be built b

Strany 8 - QV32B, QV36B

16 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06NOTE: PIPES OVERLAP 1-1/4 INCHES(34.93mm) AT EACH JOINT.Figure 6. DVP-Series Direct Ve

Strany 9 - Approvals and Codes

17Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06NOTE: PIPES OVERLAP 1-3/8 INCHES (34.93mm) AT EACH JOINT.Figure 7. SL D-Series Direct Ve

Strany 10 - Massachusetts

18 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Step 3. Installing the Vent SystemA. Vent System ApprovalsThese models have vent starti

Strany 11 - Getting Started

19Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06STRAIGHT UPVERTICAL VENTINGV (FT.)45' MAX.Figure 10.Straight up Vertical VentingUse S

Strany 12

2 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06These units MUST use one of the vent systemsdescribed in the Installing the Fireplace sect

Strany 13

20 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Figure 13. Venting with One 90° ElbowUse SL D-Seriescomponents only.MODEL QV32BV (MIN.) H

Strany 14 - Installing the Fireplace

21Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06V H H + H11' MIN. (305 mm) 2' MAX. (610 mm) 4' MAX. (1.22m)2' MIN.

Strany 15

22 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Figure 15. Venting with Two 90° ElbowsMODEL QV32BV (MIN.) H + H1 (MAX.)90o Elbow on Top

Strany 16 - (34.93mm) AT EACH JOINT

23Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Figure 16. Venting with Two 90° ElbowsMODEL QV32BV (MIN.) H (MAX.)90o Elbow on Top 2.5 FT

Strany 17

24 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Figure 17. Venting with Three 90° elbows1' MIN. (305 mm) 2' MAX. (610mm) 4&

Strany 18 - Identifying Vent Components

25Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Figure 18. Venting with three 90° elbowsUse SL D-Series components only. MODEL QV

Strany 19 - Flex Vent

26 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Use SL D-Series components only.Figure 19. Venting with three 90° elbowsMODEL QV32BV (MIN

Strany 20

27Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Figure 20. Venting with Four 90° elbowsVENTING WITH FOUR (4) 90° ELBOWS NATURAL AND PRO

Strany 21 - Use DVP-Series

28 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06B. Installing Vent ComponentsAfter determining which set of starting collars will be use

Strany 22 - Use SL D-Series

29Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06For Vertical Runs - The vent system must be supportedevery eight (8) feet (2.4m) above the

Strany 23

3Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06TABLE OF CONTENTSSafety and Warning Information ...

Strany 24 - components only

30 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06For Vertical Runs - One ceiling firestop is REQUIRED atthe hole in each ceiling through w

Strany 25

31Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06C. Vent TerminationSL-Series Venting Only:For Horizontal Terminations - To attach and sec

Strany 26

32 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06V= VENT TERMINALX= AIR SUPPLY INLET= AREA WHERE TERMINAL IS NOT PERMITTED Figure 30.

Strany 27 - 90° ELBOWS

33Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06For Vertical Terminations - To locate the vent and installthe vent sections:• Locate and m

Strany 28 - DVP Series Venting Only:

34 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Step 4. Positioning, Leveling, and Securing the Fireplace• Place the firep

Strany 29

35Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Figure 34. Gas Supply Line• Insert insulation from the outside of the fireplace andpack

Strany 30

36 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Step 8. Wiring the FireplaceNOTE: Electrical wiring must be installed by a licensedelect

Strany 31 - For All Venting:

37Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Step 9. FinishingFigure 38 shows the minimum vertical and correspondingmaximum horizontal

Strany 32 - (See Note 5)

38 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Placing the Ember MaterialEmber material is shipped with this gas fireplace. The baglabel

Strany 33 - (DVP PIPE)

39Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Step 11. Lighting the ApplianceSTANDING PILOT IGNITIONA. This appliance (standing pilot

Strany 34 - STANDING PILOT

4 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06* Part number list on following page.542136 Log Set Assembly11108791312(NG, LP) Exploded

Strany 35 - Step 6. The Gas Supply Line

40 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Step 12. Before Lighting the FireplaceBefore lighting the fireplace, be sure to do the

Strany 36 - Step 8. Wiring the Fireplace

41Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/064Maintaining and Servicing Your FireplaceFireplace MaintenanceAlthough the frequency of yo

Strany 37 - Step 9. Finishing

42 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06TroubleshootingWith proper installation, operation, and maintenance your gas fireplacewil

Strany 38 - EMBER MATERIALS

43Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Symptom Possible Cause Corrective Action3. (Continued) f. High limit switch is defective o

Strany 39

44 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Lifetime WarrantyLIMITED LIFETIME WARRANTYThe Hearth & Home Technologies limited Life

Strany 40 - After the Installation

5Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06AVAILAB LETO SHIP IN24 HOURSITEM STANDING PILOT IGNITION SERIAL # PART NUMBERBurner Orifice

Strany 41 - Fireplace Maintenance

6 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06* Part number list on following page.46 Log Set Assembly1111087952312(NG, LP) Exploded Pa

Strany 42 - Troubleshooting

7Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06(NG, LP) Service Parts List /IMPORTANT: THIS IS DATED INFORMATION. The most current inform

Strany 43 - Troubleshooting (continued)

8 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06(NG, LP) Exploded Parts DiagramService PartsQV32B, QV36BBeginning Manufacturing Date: 7-0

Strany 44 - Lifetime Warranty

9Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/061Approvals and CodesNOTE: THESE MODELS ARE UL LISTED TO UL307B,THE STANDARD FOR GAS-BURNING